04634-6 | |
Certificate Type | CERTIFICATE OF NDT AND VISUAL INSPECTION |
Cert# | 04634-6 |
Customer | WIRELINE CONTROL SYSTEMS |
Certificate Type | CERTIFICATE OF NDT AND VISUAL INSPECTION |
Unit# | 12114 |
Test Performed | MAGNETIC PARTICLE |
Test Result | ACCEPTED |
Descripiton | 4 PAD EYE MAGNETIC PARTICLE INSPECTION ON BASKET |
Date of Inspection | 09/01/2022 |
Description | |
Height | 3'6" |
Length | 12' |
Width | 4' |
Tare | 2,620 LBS |
WLL | 19,960 LBS |
MGW | 22,580 LBS |
Equipment Used | YOKE SERIAL# FTI-N-1403/ TEST BAR SERIAL# 17880/ LIGHT METER SERIAL# 171001668/ WET PARTICLES: 820S/ WCP |
Inspector | JOSEPH CELESTINE |
Inspector Certifications | LEVEL II MT, PT |
Inspector Signature | |
Download Certificate PDF | Download Cert |