04615-1 | |
| Certificate Type | CERTIFICATE OF LOAD TEST AND NDT INSPECTION |
| Cert# | 04615-1 |
| Customer | EXPRO GROUP |
| Certificate Type | CERTIFICATE OF LOAD TEST AND NDT INSPECTION |
| Unit# | 08-XGM-012 |
| Test Performed | LOAD TEST/ MAGNETIC PARTICLE |
| Test Result | ACCEPTED |
| Descripiton | 2 PAD EYE LOAD TEST AND MAGNETIC PARTICLE INSPECTION ON BURNER BOOM HANGING PAD EYES. (PROOF LOAD APPLIED: 39,000 LBS) 2 PAD EYE LOAD TEST AND MAGNETIC PARTICLE INSPECTION ON BURNER BOOM WIND STAY PAD EYES. (PROOF LOAD APPLIED: 26,000 LBS) |
| Date of Inspection | 08/25/2022 |
Description | |
| Height | 4'2" |
| Length | 30' |
| Width | 4' |
| Tare | N/A |
| WLL | N/A |
| MGW | 15,600 LBS & 10,400 LBS |
| Equipment Used | LOAD TEST UNIT SERIAL# FTI-P392/ YOKE SERIAL# FTI-N-1403/ TEST BAR SERIAL# 17880/ LIGHT METER SERIAL# 171001668/ WET PARTICLES: 820S/ WCP |
| Inspector | COREY NAVARRO |
| Inspector Certifications | LEVEL II MT, PT, VT |
| Inspector Signature | |