04509-5 | |
Certificate Type | CERTIFICATE OF LOAD TEST AND NDT INSPECTION |
Cert# | 04509-5 |
Customer | BLUEFIN SERVICES |
Certificate Type | CERTIFICATE OF LOAD TEST AND NDT INSPECTION |
Unit# | 550SSTT-021 |
Test Performed | LOAD TEST/ LIQUID PENETRANT |
Test Result | ACCEPTED |
Descripiton | 4 PAD EYE LOAD TEST AND LIQUID PENETRANT INSPECTION ON TOTE TANK (PROOF LOAD APPLIED: 23,365 LBS) |
Date of Inspection | 07/25/2022 |
Description | |
Height | 6'3" |
Length | 4' |
Width | 3'6" |
Tare | 631 LBS |
WLL | 8,715 LBS |
MGW | 9,346 LBS |
Equipment Used | LOAD TEST UNIT SERIAL# FTI-P392/ LIGHT METER SERIAL# 180404010/ WET PARTICLES: DP-51/ D-106 |
Inspector | DREW PENNISON |
Inspector Certifications | LEVEL II MT, PT |
Inspector Signature | |
Download Certificate PDF | Download Cert |