04870-1 | |
Certificate Type | CERTIFICATE OF LOAD TEST AND NDT INSPECTION |
Cert# | 04870-1 |
Customer | HALLIBURTON |
Certificate Type | CERTIFICATE OF LOAD TEST AND NDT INSPECTION |
Unit# | WDH-10T-3 |
Test Performed | LOAD TEST/ MAGNETIC PARTICLE |
Test Result | ACCEPTED |
Descripiton | LOAD TEST AND MAGNETIC PARTICLE INSPECTION ON 10 TON SHEAVE.(PROOF LOAD APPLIED: 40,000 LBS) |
Date of Inspection | 11/30/2022 |
Description | |
Height | 1'9" |
Length | 3'1" |
Width | 4" |
WLL | 20,000 LBS |
Equipment Used | LOAD TEST UNIT SERIAL# FTI-P391/ YOKE SERIAL# FTI-N-1301/ TEST BAR SERIAL# 22607/ LIGHT METER SERIAL# 180404010/ WET PARTICLES: 820A/WCP |
Inspector | DREW PENNISON |
Inspector Certifications | LEVEL II MT, PT |
Inspector Signature | |
Download Certificate PDF | Download Cert |